Refrigeration Systems

Monoblock Refrigerator System KT 180 - Ceiling Design

Connector-ready cooling unit, which is ready for immediate use. Mounted directly on top of the morgue. The units have a sturdy housing with low-noise emittance, are fully thermal, and equipped with an air-cooled compressor. The safety utilities are in accordance with EN (DIN) standards, VDE regulations and VBG guidelines. Also included is a high-capacity evaporator with automatic defrosting, an electrical temperature regulation and a digital temperature indicator with connection and protective plug.

  • Refrigerant: R 134 A
  • GWP: 1430
  • Ambient temperature +5°C up to +45°C

Technical Data

Temperature range:
Voltange:
Refrigeration capacity 0°C inside, +40°C outside:
Rated Input (when normally running):
Rated input:
Peak current:
Max. current:
Defrost:
Weight:
Filling quantity refrigerant:

Compressor:
Type:
Normal power:

Condenser:
Air flow:

Evaporator:
Air flow:
Air throw:
Dimensions W/D/H:
Dimensions opening W/D:
Type:
Article No.:
+10°C to -5°C
230 V / 1 Ph / 50 Hz
1601 Watt
1000 Watt
5.6 Amp
38 Amp
11.1 Amp
hot gas defrosting
74 kg
0.75 kg


hermetic
900 Watt


1400 m³/h


1100 m³/h
4 m (Standard)
820 x 809 x 390 mm
750 x 337 mm
KT 180 - R 134A
040.100.087