Formalin Disposal Station, Width 1200 mm Special working table with integrated ventilation system for disposing used formalin and histological tissue samples. The air is being vacuumed downwards throughout the entire work area to guarantee the best possible removal of unsanitary vapors. MAC (maximum allowable concentration) values for formalin are below target throughout the entire vacuum-effected area. The working table has to be connected to an exhaust-air-system provided by the customer. - Completely made of brushed stainless steel (material no. 1.4301 – ANSI 304) - Sturdy, self-supporting substructure with wing doors at the front side. - Perforated working area with removable separating screen with folding mechanism for separating liquids from solid material. - An eye shower with shower head is mounted to the table - Very sturdy, perforated sheet inserts (approximately 10 mm lower than the circumferential edge) with D17, T760 drilling - Exhaust air capacity at the perforated sheet inserts min. 0.4 m/sec - Integrated exhaust air connection with air flow rate regulation - Exhaust air connection can be installed at the left or right side of the table - 20 liters tank with sensor level for used formalin - Tank for disposed histological tissue samples is not included in scope of delivery Technical data: Dimensions W/D/H: 1200 x 850 x 850 mm Exhaust air capacity: min. 1000 m³/h Material: ground stainless steel (material no. 1.4301 – ANSI 304) Cold-/Hot-water connection: DN 15 Waste water connection: DN 50 Exhaust air connection: DN 200 Type: ESS-1200 Formalin Disposal Station, Width 1500 mm Special working table with integrated ventilation system for disposing used formalin and histological tissue samples. The air is being vacuumed downwards throughout the entire work area to guarantee the best possible removal of unsanitary vapors. MAC (maximum allowable concentration) values for formalin are below target throughout the entire vacuum-effected area. The working table has to be connected to an exhaust-air-system provided by the customer. - Completely made of brushed stainless steel (material no. 1.4301 – ANSI 304) - Sturdy, self-supporting substructure with wing doors at the front side. - Perforated working area with removable separating screen with folding mechanism for separating liquids from solid material. - An eye shower with shower head is mounted to the table - Very sturdy, perforated sheet inserts (approximately 10 mm lower than the circumferential edge) with D17, T760 drilling - Exhaust air capacity at the perforated sheet inserts min. 0.4 m/sec - Integrated exhaust air connection with air flow rate regulation - Exhaust air connection can be installed at the left or right side of the table - 20 liters tank with sensor level for used formalin - Tank for disposed histological tissue samples is not included in scope of delivery Technical data: Dimensions W/D/H: 1500 x 850 x 850 mm Exhaust air capacity: min. 1200 m³/h Material: ground stainless steel (material no. 1.4301 – ANSI 304) Cold-/Hot-water connection: DN 15 Waste water connection: DN 50 Exhaust air connection: DN 200 Type: ESS-1500 Formalin Disposal Station, Width 1750 mm Special working table with integrated ventilation system for disposing used formalin and histological tissue samples. The air is being vacuumed downwards throughout the entire work area to guarantee the best possible removal of unsanitary vapors. MAC (maximum allowable concentration) values for formalin are below target throughout the entire vacuum-effected area. The working table has to be connected to an exhaust-air-system provided by the customer. - Completely made of brushed stainless steel (material no. 1.4301 – ANSI 304) - Sturdy, self-supporting substructure with wing doors at the front side. - Perforated working area with removable separating screen with folding mechanism for separating liquids from solid material. - An eye shower with shower head is mounted to the table - Very sturdy, perforated sheet inserts (approximately 10 mm lower than the circumferential edge) with D17, T760 drilling - Exhaust air capacity at the perforated sheet inserts min. 0.4 m/sec - Integrated exhaust air connection with air flow rate regulation - Exhaust air connection can be installed at the left or right side of the table - 20 liters tank with sensor level for used formalin - Tank for disposed histological tissue samples is not included in scope of delivery Technical data: Dimensions W/D/H: 1750 x 850 x 850 mm Exhaust air capacity: min. 1500 m³/h Material: ground stainless steel (material no. 1.4301 – ANSI 304) Cold-/Hot-water connection: DN 15 Waste water connection: DN 50 Exhaust air connection: DN 20 Type: ESS-1750 Formalin Disposal Station, Width 2000 mm Special working table with integrated ventilation system for disposing used formalin and histological tissue samples. The air is being vacuumed downwards throughout the entire work area to guarantee the best possible removal of unsanitary vapors. MAC (maximum allowable concentration) values for formalin are below target throughout the entire vacuum-effected area. The working table has to be connected to an exhaust-air-system provided by the customer. - Completely made of brushed stainless steel (material no. 1.4301 – ANSI 304) - Sturdy, self-supporting substructure with wing doors at the front side. - Perforated working area with removable separating screen with folding mechanism for separating liquids from solid material. - An eye shower with shower head is mounted to the table - Very sturdy, perforated sheet inserts (approximately 10 mm lower than the circumferential edge) with D17, T760 drilling - Exhaust air capacity at the perforated sheet inserts min. 0.4 m/sec - Integrated exhaust air connection with air flow rate regulation - Exhaust air connection can be installed at the left or right side of the table - 20 liters tank with sensor level for used formalin - Tank for disposed histological tissue samples is not included in scope of delivery Technical data: Dimensions W/D/H: 2000 x 850 x 850 mm Exhaust air capacity: min. 1600 m³/h Material: ground stainless steel (material no. 1.4301 – ANSI 304) Cold-/Hot-water connection: DN 15 Waste water connection: DN 50 Exhaust air connection: DN 20 Type: ESS-2000 Formalin Disposal Station, Width 2500 mm Special working table with integrated ventilation system for disposing used formalin and histological tissue samples. The air is being vacuumed downwards throughout the entire work area to guarantee the best possible removal of unsanitary vapors. MAC (maximum allowable concentration) values for formalin are below target throughout the entire vacuum-effected area. The working table has to be connected to an exhaust-air-system provided by the customer. - Completely made of brushed stainless steel (material no. 1.4301 – ANSI 304) - Sturdy, self-supporting substructure with wing doors at the front side. - Perforated working area with removable separating screen with folding mechanism for separating liquids from solid material. - An eye shower with shower head is mounted to the table - Very sturdy, perforated sheet inserts (approximately 10 mm lower than the circumferential edge) with D17, T760 drilling - Exhaust air capacity at the perforated sheet inserts min. 0.4 m/sec - Integrated exhaust air connection with air flow rate regulation - Exhaust air connection can be installed at the left or right side of the table - 20 liters tank with sensor level for used formalin - Tank for disposed histological tissue samples is not included in scope of delivery Technical data: Dimensions W/D/H: 2500 x 850 x 850 / 1150 mm Exhaust air capacity: minimum 1800 m³/h Material: ground stainless steel (material no. 1.4301 – ANSI 304) Cold-/Hot-water connection: DN 15 Waste water connection: DN 50 Exhaust air connection: DN 20 Type: ESS-2500